The Air handling Unit is the most important part of the HVAC system which is designed to regulate and circulate air throughout a space.
Climate grip private limited is committed to Manufacture world class high efficiency Air Handling Unit as well as reputed AHU unit supplier. Since its establishment in 2001, Climate Grip has remarkably achieved a well-known position as a best Air Handling Unit Manufacturer in India. Our AHU manufacturers in various configurations- Floor Mounted Type, Vertical Type and customized one as per customer specific requirements. These all are responsible for providing fresh air in your spaces.
Being the heart of HVAC systems, Our air handling unit manages ventilation by collecting outdoor air and room air, filtering the air , adjusting the humidity and temperature, and distributing a comfortable and refreshing supply of air-conditioning through ductwork inside the spaces. The capacity of these units are commonly measured by the amount of air conditions and distributes. Calculation of this measurement in volumetric units are as CFM (cubic feet per minute)
AHU Manufacturer in India
The Air handling Unit commonly known as AHU, Climate Grip Manufacture for various types of spaces such as hotels, restaurants, dining halls, conference or convention centers and so on. These units restrict natural ventilation due to their high volume of simultaneous visitors.
However, AHU is also a good solution for locations with strict hygiene regulations, like manufacturing facilities, clean rooms, medical, operating rooms, and laboratories. Along with that, It can also be utilised to ventilate spaces that, for instance, have underfloor heating or radiators for air conditioning. AHU is also suitable for those spaces with very hygiene requirements, laboratories, operation theater etc.
Air Handling unit in HVAC
The AHU is the most important part of your HVAC systems which make sure to have fresh, clean and comfortable air in your home or office.
However, we all know air can get dirty very quickly and if it’s not cleaned regularly, mold or mildew will start to form on the coil inside your AC unit. This is why regular maintenance is necessary to keep your AC long lasting.
Climate Grip manufactures the Air Handling Unit with a heavy-duty extruded aluminum profile, offering options with or without a thermal break and internal coaming sections. These unit panels are filled with pressure-injected polyurethane foam, having a thickness of 25 or 50 mm and a density of 38/40 kg/m3.
Parts of an Air Handling Unit
We will know about the parts of an Air Handling Unit which can help you to understand the overall functions of systems.
- Filter- The Filter depends on the purity requirements of the buildings.
- Air Intake- Collect air from the outdoors to be treated and distributed indoors.
- The Cooling Coil – It is defined as a versatile and efficient cooling system, it allows easy integration into different spaces and configuration.
- Fan- Expels the air from the AHU into the duct system that distributes the conditioned air.
- Heat Exchangers- By the AHU, these devices transfer temperature between the air and the coolants.
- Plenums – They are strategically placed empty spaces within the unit where airflow is allowed to homogenize.
- Silencer- During the time of operations, special coatings are applied to the unit walls to help reduce the noise level.
Types of Air Handling Unit:
The various types of Air handling Unit are
Horizontal and Vertical Units – : Horizontal units are said to be as the components are placed at the same horizontal level. Whereas, Vertical units typically require less floor area and are placed on top of another.
Draw- through Units- : Draw through is a type of AHU which can either be horizontal or vertical. Before the air enters the ducting network, it is pulled through the mixing box, cooling coil, and filters by a fan. These units could be limited to a coil, blower and air filter. The other name of the Draw through unit is fresh air handling unit.
Blow- through Units- : Before the air enters the ducting network, the blow- through air handling unit’s fan forces the air through the mixing box, cooling coil and filters.
Single Zone and Multi Zone Units- : Single Zone requires an outdoor and indoor unit with a line st, cable and drain line. But for dual duct systems, a multi zone AHU is more frequently employed.
Rooftop and Indoor Units- : These units are specific AHU made for outside usage. They resist corrosion and are typically positioned on the roof. However, the majority of Air Handling Units are indoor units.
Custom-built and Field-built Units -: Standard Units are less expensive and can be delivered more quickly. Custom- built units can be customized to be the most energy- efficient alternative and offer greater versatility.
Purpose of an Air Handling Unit
The main purpose of an Air Handling Unit is to increase and improve energy efficiency. Heat exchanger cooler units and specialized in coils work together to collect and reprocess waste heat through the AHU. Indoors and Outside air are mixed during the cooler process and help to reduce the extreme hot/cold contrast when the air reaches the cooling coil and enable the unit to produce cool air with the least amount of energy.
Conclusion:
While installing the Air Handling Unit, Climate Grip provides you the best specialist teams to install the AHU systems and do not cut corners on commissioning as it will save your money. It is important to increase operational efficiency and conserve energy, reconfigure or update components.